    A Proof of Concept Study of the Mechanical Behavior of Lattice Structures Used to Design a Shoulder Hemi-Prosthesis

    Thumbnail
    View/Open
    jesmdt_004_03_031004.pdf (3.367Mb)
    Date
    2021
    Author
    Peto, Marinela
    Aguilar-Rosas, Oscar
    Ramirez-Cedillo, Erick
    Jimenez, Moises
    Hernandez, Adriana
    Siller, Hector R.
    Metadata
    Show full item record
    Abstract
    Lattice structures offer great benefits when employed in medical implants for cell attachment and growth (osseointegration), minimization of stress shielding phenomena, and weight reduction. This study is focused on a proof of concept for developing a generic shoulder hemi-prosthesis, from a patient-specific case of a 46-years-old male with a tumor on the upper part of his humerus. A personalized biomodel was designed and a lattice structure was integrated in its middle portion, to lighten weight without affecting humerus' mechanical response. To select the most appropriate lattice structure, three different configurations were initially tested: tetrahedral vertex centroid (TVC), hexagonal prism vertex centroid (HPVC), and cubic diamond (CD). They were fabricated in resin by digital light processing and its mechanical behavior was studied via compression testing and finite element modeling (FEM). The selected structure according to the results was the HPVC, which was integrated in a digital twin of the biomodel to validate its mechanical performance through FEM but substituting the bone material model with a biocompatible titanium alloy (Ti6Al4V) suitable for prostheses fabrication. Results of the simulation showed acceptable levels of Von Mises stresses (325 MPa max.), below the elastic limit of the titanium alloys, and a better response (52 MPa max.) in a model with equivalent elastic properties, with stress performance in the same order of magnitude than the showed in bone's material model.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278534
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV