• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effect of Vessel Tortuosity on Stress Concentration at the Distal Stent–Vessel Interface: Possible Link With New Entry Formation Through Biomechanical Simulation

    Thumbnail
    View/Open
    bio_143_08_081005.pdf (2.154Mb)
    Date
    2021
    Author
    Tan, Wei Ting
    Liew, Yih Miin
    Mohamed Mokhtarudin, Mohd Jamil
    Pirola, Selene
    Wan Ab Naim, Wan Naimah
    Amry Hashim, Shahrul
    Xu, Xiao Yun
    Lim, Einly
    Metadata
    Show full item record
    Abstract
    A computational approach is used to investigate potential risk factors for distal stent graft-induced new entry (dSINE) in aortic dissection (AD) patients. Patient-specific simulations were performed based on computed tomography images acquired from six AD patients (three dSINE and three non-dSINE) to analyze the correlation between anatomical characteristics and stress/strain distributions. Sensitivity analysis was carried out using idealized models to independently assess the effect of stent graft length, stent tortuosity and wedge apposition angle at the landing zone on key biomechanical variables. Mismatch of biomechanical properties between the stented and nonstented regions led to high stress at the distal stent graft–vessel interface in all patients, as well as shear strain in the neighboring region, which coincides with the location of tear formation. Stress was observed to increase with the increase of stent tortuosity (from 263 kPa at a tortuosity angle of 50 deg to 313 kPa at 30 deg). It was further amplified by stent graft landing at the inflection point of a curve. Malapposition of the stent graft led to an asymmetrical segment within the aorta, therefore changing the location and magnitude of the maximum von Mises stress substantially (up to +25.9% with a +25 deg change in the distal wedge apposition angle). In conclusion, stent tortuosity and wedge apposition angle serve as important risk predictors for dSINE formation in AD patients.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278108
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV