    Performance Evaluation of a Single-Stage Two-Bed Adsorption Chiller With Desalination Function

    Thumbnail
    View/Open
    jert_143_8_082101.pdf (869.4Kb)
    Date
    2020
    Author
    Sztekler, Karol
    Kalawa, Wojciech
    Nowak, Wojciech
    Mika, Łukasz
    Krzywański, Jarosław
    Grabowska, Karolina
    Sosnowski, Marcin
    Alharbi, Ahmed A.
    Metadata
    Show full item record
    Abstract
    Energy efficiency is one of the most important topics nowadays. It is strictly related to the problem of energy demand, energy policy, environmental pollution, and economic issues. Because of the technological development, using more advanced processes in almost every part of industry and increasing demands both for a high standard of living and simplification of processes, the energy demand is growing. This can be observed, e.g., in the building sector—air conditioning is present in almost every new building and people expect high quality thermal conditions. At the same time, many technological processes result in dissipating energy to the environment. Energy efficiency can be increased and operation costs reduced by using waste heat in other processes. One of the possibilities is to use sorption chillers to produce cool and desalinated water. Low temperature waste heat is not easy to utilize because of low energy potential. Using adsorption chillers in low temperature conditions allows utilizing waste heat and producing useful products in many regions of the world. The paper presents the results of experimental study carried out on three-bed adsorption chiller with desalination, using silica gel and water as the working pair. The chiller was equipped with plate-fin tube heat exchanger filled with silica gel with a grain size of 0.5–1.5 mm. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stand scheme and description were presented. All results were obtained during a few hours test with stable temperature conditions in the range of 55–85 °C for the heating water.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277916
    Collections
    • Journal of Energy Resources Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV