    Fully Coupled Large Eddy Simulation-Conjugate Heat Transfer Analysis of a Ribbed Cooling Passage Using the Immersed Boundary Method

    Thumbnail
    View/Open
    turbo_143_4_041012.pdf (1.242Mb)
    Date
    2021
    Author
    Oh, Tae Kyung
    Tafti, Danesh K.
    Nagendra, Krishnamurthy
    Metadata
    Show full item record
    Abstract
    The study focuses on evaluating fully coupled conjugate heat transfer (CHT) simulation in a ribbed cooling passage with a fully developed flow assumption using large eddy simulation (LES) with the immersed boundary method (IBM-LES-CHT). The IBM-LES and the IBM-CHT frameworks are validated by simulating purely convective heat transfer in the ribbed duct, and a laminar boundary layer flow over a 2D flat plate with heat conduction, respectively. For the main conjugate simulations, a ribbed duct geometry with a blockage ratio of 0.3 is simulated at a bulk Reynolds number of 10,000 with a conjugate boundary condition applied to the rib surface. The nominal Biot number is kept at 1, which is similar to the comparative experiment. It is shown that the time scale disparity between turbulent fluid flow and heat conduction in solid can be overcome by using an artificially high solid thermal diffusivity. While the diffusivity impacts the instantaneous fluctuations in temperature and heat transfer, it has an insignificant effect on the predicted Nusselt number. Comparison between IBM-LES-CHT and iso-flux heat transfer simulations shows that the iso-flux case predicts higher local Nusselt numbers at the back face of the rib. Furthermore, the local Nusselt number augmentation ratio (EF) predicted by IBM-LES-CHT is compared with experiment and another LES conjugate simulation. The present LES calculations predict higher EFs on the leading face of the rib and show a different trend at the trailing face when CHT is activated.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276979
    Collections
    • Journal of Turbomachinery

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV