    A Methodology to Evaluate the Effects of Kinematic Measurement Uncertainties on Knee Ligament Properties Estimated From Laxity Measurements

    Thumbnail
    View/Open
    bio_143_06_061003.pdf (1017.Kb)
    Date
    2021
    Author
    Andersen, Michael Skipper
    Dzialo, Christine Mary
    Marra, Marco Antonio
    Pedersen, Dennis
    Metadata
    Show full item record
    Abstract
    Ligaments are important joint stabilizers but assessing their mechanical properties remain challenging. We developed a methodology to investigate the effects of kinematic measurement uncertainty during laxity tests on optimization-based estimation of ligament properties. We applied this methodology to a subject-specific knee model with known ligament properties as inputs and compared the estimated to the known knee ligament properties under the influence of noise. Four different sets of laxity tests were simulated with an increasing number of load cases, capturing anterior/posterior, varus/valgus, and internal/external rotation loads at 0 deg and 30 deg of knee flexion. 20 samples of uniform random noise ([−0.5,0.5] mm and degrees) were added to each set and fed into an optimization routine that subsequently estimated the ligament properties based on the noise targets. We found a large range of estimated ligament properties (stiffness ranges of 5.97 kN, 7.64 kN, 8.72 kN, and 3.86 kN; reference strain ranges of 3.11%, 2.53%, 1.88%, and 1.58% for anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medical collateral ligament (MCL), and lateral collateral ligament (LCL), respectively) for three sets of laxity tests, including up to 22 load cases. A set of laxity tests with 60 load cases kept the stiffness and reference strain ranges below 470 N per unit strain and 0.85%, respectively. These results illustrate that kinematic measurement noise have a large impact on estimated ligament properties and we recommend that future studies assess and report both the estimated ligament properties and the associated uncertainties due to kinematic measurement noise.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276057
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV