Show simple item record

dc.contributor.authorHargett, Zachary
dc.contributor.authorGutierrez, Manuel
dc.contributor.authorHarman, Melinda
dc.date.accessioned2022-02-04T23:02:38Z
dc.date.available2022-02-04T23:02:38Z
dc.date.copyright9/1/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn2377-2158
dc.identifier.othervvuq_005_03_031004.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275977
dc.description.abstractCadaveric testing is a common approach for verifying mathematical algorithms in computational modeling. In models of total knee replacement (TKR) motion, model inputs commonly include rigid body motions defined using the Grood–Suntay spatial linkage between tibial and femoral components. This approach requires definition of coordinate systems for each rigid TKR component based on fiducial points, manual digitization of a point cloud within the experimental setup, and registration of the orientation relative to bone marker arrays. This study compared variability between two different manual point digitization methods (hand-held stylus and pivot tool each registered in an optical tracking system). This was accomplished by verifying the mathematical algorithm used to calculate the coordinate system from digitized points and quantifying the variability of the digitization methods in a simulated cadaver limb experimental setup. For the hand-held stylus method, the standard deviation was 0.50 mm for the origin and 1.31, 0.51, and 0.62 deg for the x–y–z axes, respectively. Required digitization of each rigid marker array created additional errors of 0.54 mm for the origin and 1.70, 1.66, and 0.98 deg for the x–y–z axes, respectively. For the pivot tool method, the standard deviation was 0.35 mm for the origin and 0.37, 1.27, and 1.24 deg for the x–y–z axes, respectively. In this experimental setup, the pivot tool was the better option for minimizing error while providing repeatable manual digitization of fiducial points and point clouds.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleVerification of Manual Digitization Methods During Experimental Simulation of Knee Motion
dc.typeJournal Paper
dc.journal.volume5
dc.journal.issue3
dc.journal.titleJournal of Verification, Validation and Uncertainty Quantification
dc.identifier.doi10.1115/1.4048748
dc.journal.fristpage031004-1
dc.journal.lastpage031004-5
dc.page5
dc.treeJournal of Verification, Validation and Uncertainty Quantification:;2020:;volume( 005 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record