• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Engineering and Science in Medical Diagnostics and Therapy
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Embedded Spherical Microlasers for In Vivo Diagnostic Biomechanical Performances

    Thumbnail
    View/Open
    jesmdt_003_04_044504.pdf (810.9Kb)
    Date
    2020
    Author
    Manzo, Maurizio
    Cavazos, Omar
    Ramirez-Cedillo, Erick
    Siller, Hector R.
    Metadata
    Show full item record
    Abstract
    In this article, we propose to use spherical microlasers that can be attached to the surface of bones for in vivo strain monitoring applications. The sensing element is made of mixing polymers, namely, PEGDA-700 (Sigma Aldrich, St. Louis, MO) and Thiocure TMPMP (Evan Chemetics, Teaneck, NJ) at 4:1 ratio in volume doped with rhodamine 6G (Sigma Aldrich, St. Louis, MO) laser dye. Solid-state microlasers are fabricated by curing droplets from the liquid mixture using ultraviolet (UV) light. The sensing principle relies on morphology-dependent resonances; any changes in the strain of the bone causes a shift of the optical resonances, which can be monitored. The specimen is made of a simulated cortical bone fabricated with photopolymer resin via an additive manufacturing process. The light path within the resonator is found to be about perpendicular to the normal stress' direction caused by a bending moment. Therefore, the sensor measures the strain due to bending indirectly using the Poisson effect. Two experiments are conducted: 1) negative bone deflection (called loading) and 2) positive bone deflection (called unloading) for a strain range from 0 to 2.35 × 10−3 m/m. Sensitivity values are ∼19.489 and 19.660 nm/ε for loading and unloading experiments, respectively (percentage difference is less than 1%). In addition, the resolution of the sensor is 1 × 10−3 ε (m/m) and the maximum range is 11.58 × 10−3 ε (m/m). The quality factor of the microlaser is maintaining about constant (order of magnitude 104) during the experiments. This sensor can be used when bone location accessibility is problematic.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4275048
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV