Show simple item record

dc.contributor.authorNatesan, Harishankar
dc.contributor.authorTian, Limei
dc.contributor.authorA. Rogers, John
dc.contributor.authorBischof, John
dc.date.accessioned2022-02-04T22:07:38Z
dc.date.available2022-02-04T22:07:38Z
dc.date.copyright9/8/2020 12:00:00 AM
dc.date.issued2020
dc.identifier.issn0148-0731
dc.identifier.otherbio_142_12_121003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274929
dc.description.abstractTreatment of atrial fibrillation by cryoablation of the pulmonary vein (PV) suffers from an inability to assess probe contact, tissue thickness, and freeze completion through the wall. Unfortunately, clinical imaging cannot be used for this purpose as these techniques have resolutions similar in scale (∼1 to 2 mm) to PV thickness and therefore are unable to resolve changes within the PV during treatment. Here, a microthermal sensor based on the “3ω” technique which has been used for thin biological systems is proposed as a potential solution and tested for a cryoablation scenario. First, the sensor was modified from a linear format to a serpentine format for integration onto a flexible balloon. Next, using numerical analyses, the ability of the modified sensor on a flat substrate was studied to differentiate measurements in limiting cases of ice, water, and fat. These numerical results were then complemented by experimentation by micropatterning the serpentine sensor onto a flat substrate and onto a flexible balloon. In both formats (flat and balloon), the serpentine sensor was experimentally shown to: (1) identify tissue contact versus fluid, (2) distinguish tissue thickness in the 0.5 to 2 mm range, and (3) measure the initiation and completion of freezing as previously reported for a linear sensor. This study demonstrates proof of principle that a serpentine 3ω sensor on a balloon can monitor tissue contact, thickness, and phase change which is relevant to cryo and other focal thermal treatments of PV to treat atrial fibrillation.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Microthermal Sensor for Cryoablation Balloons
dc.typeJournal Paper
dc.journal.volume142
dc.journal.issue12
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4047134
dc.journal.fristpage0121003-1
dc.journal.lastpage0121003-9
dc.page9
dc.treeJournal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record