• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Microthermal Sensor for Cryoablation Balloons

    Thumbnail
    View/Open
    bio_142_12_121003.pdf (1.352Mb)
    Date
    2020
    Author
    Natesan, Harishankar
    Tian, Limei
    A. Rogers, John
    Bischof, John
    Metadata
    Show full item record
    Abstract
    Treatment of atrial fibrillation by cryoablation of the pulmonary vein (PV) suffers from an inability to assess probe contact, tissue thickness, and freeze completion through the wall. Unfortunately, clinical imaging cannot be used for this purpose as these techniques have resolutions similar in scale (∼1 to 2 mm) to PV thickness and therefore are unable to resolve changes within the PV during treatment. Here, a microthermal sensor based on the “3ω” technique which has been used for thin biological systems is proposed as a potential solution and tested for a cryoablation scenario. First, the sensor was modified from a linear format to a serpentine format for integration onto a flexible balloon. Next, using numerical analyses, the ability of the modified sensor on a flat substrate was studied to differentiate measurements in limiting cases of ice, water, and fat. These numerical results were then complemented by experimentation by micropatterning the serpentine sensor onto a flat substrate and onto a flexible balloon. In both formats (flat and balloon), the serpentine sensor was experimentally shown to: (1) identify tissue contact versus fluid, (2) distinguish tissue thickness in the 0.5 to 2 mm range, and (3) measure the initiation and completion of freezing as previously reported for a linear sensor. This study demonstrates proof of principle that a serpentine 3ω sensor on a balloon can monitor tissue contact, thickness, and phase change which is relevant to cryo and other focal thermal treatments of PV to treat atrial fibrillation.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274929
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV