• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design and Biomechanical Analysis of a Novel Retrievable Peripheral Vascular Stent

    Thumbnail
    View/Open
    med_014_02_025006.pdf (2.291Mb)
    Date
    2020
    Author
    Guo, Jingzhen
    Mao, Lin
    Yu, Xitong
    Song, Chengli
    Zhao, Xue
    Metadata
    Show full item record
    Abstract
    Structurally retrievable drug-eluting stents may have valuable clinical applications because they do not leave any foreign materials inside the patient's body. This article presents a novel design of retrievable peripheral vascular stent and the results from biomechanical analysis of its performance. Using the finite element analysis method, principal parameters of the stent were studied. Moreover, to ensure the practicability of the retrieval process, simulation, and in vitro experiments were performed. The retrieval force reached the maximum value when the whole retrievable part had been retrieved. Furthermore, the force was gradually increased during the retrieval process and remained constant after the main part had been retrieved. When the stent was being compressed, the maximum strain of the stent occurred at the connection between the stent's retrieval part and the main body part, at a value of 4%. The index of nonuniformity of the stent was too small to be counted both at the end of the compression and self-expansion processes. With the increase of moment, the bending stiffness (EI) of the stent decreased gradually. After bending moment was applied, the large strain region was mainly located in the stent's main body part rather than the retrieval part. The results of preliminary stent retrieval experiments demonstrated that the stent could be retrieved successfully. This novel retrievable stent displays promising biomechanical performance. The preliminary experiments demonstrated that the stent could be retrieved smoothly from the blood vessels.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4273741
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV