Show simple item record

dc.contributor.authorM. Omar Amini
dc.contributor.authorJohn W. van de Lindt
dc.contributor.authorDouglas Rammer
dc.contributor.authorShiling Pei
dc.date.accessioned2022-02-01T00:06:23Z
dc.date.available2022-02-01T00:06:23Z
dc.date.issued9/1/2021
dc.identifier.other%28ASCE%29AE.1943-5568.0000473.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270926
dc.description.abstractCross-laminated timber (CLT) is a mass timber product that has recently garnered considerable attention for lateral-force resisting system (LFRS) applications. The main objectives of this study were to investigate the rocking behavior of a high-aspect-ratio (height/width) CLT shear wall without post-tensioning, and to validate a finite-element (FE) model based on the cyclic and dynamic response of the wall. To this point, high-aspect-ratio walls in the literature have primarily been post-tensioned. The testing component of this study included connector tests, quasistatic cyclic shear wall tests, and shake-table tests under four different ground motions scaled to design earthquake (DE)- and maximum considered earthquake (MCE)-level intensities. A generic shear connector was used for this study to allow for proprietary and other systems to demonstrate equivalence. The connectors were tested under shear and uplift, and shear-wall tests were performed using the Consortium of Universities for Research in Earthquake Engineering (CUREE) displacement protocol, which has been widely used for light-frame wood structures. Interstory drift (ISD) ratios in the shake-table tests ranged from 0.97% to 2.02%, and the tests demonstrated the system's ability to resist seismic loading. An FE model of the CLT wall was developed that showed good agreement with the cyclic and shake-table tests. The difference between the ISD ratios in the numerical model and the shake-table tests ranged from 5.4% to 31.3%, with an average of 17.9%, which was in good accordance with the accuracy of the existing CLT models. This system can be utilized as a retrofit option, in conjunction with light-frame wood shear walls, where lack of space may be a challenge.
dc.publisherASCE
dc.titleRocking Behavior of High-Aspect-Ratio Cross-Laminated Timber Shear Walls: Experimental and Numerical Investigation
dc.typeJournal Paper
dc.journal.volume27
dc.journal.issue3
dc.journal.titleJournal of Architectural Engineering
dc.identifier.doi10.1061/(ASCE)AE.1943-5568.0000473
dc.journal.fristpage04021013-1
dc.journal.lastpage04021013-12
dc.page12
dc.treeJournal of Architectural Engineering:;2021:;Volume ( 027 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record