    Rocking Behavior of High-Aspect-Ratio Cross-Laminated Timber Shear Walls: Experimental and Numerical Investigation

    Thumbnail
    View/Open
    %28ASCE%29AE.1943-5568.0000473.pdf (3.668Mb)
    Date
    9/1/2021
    Author
    M. Omar Amini
    John W. van de Lindt
    Douglas Rammer
    Shiling Pei
    Metadata
    Show full item record
    Abstract
    Cross-laminated timber (CLT) is a mass timber product that has recently garnered considerable attention for lateral-force resisting system (LFRS) applications. The main objectives of this study were to investigate the rocking behavior of a high-aspect-ratio (height/width) CLT shear wall without post-tensioning, and to validate a finite-element (FE) model based on the cyclic and dynamic response of the wall. To this point, high-aspect-ratio walls in the literature have primarily been post-tensioned. The testing component of this study included connector tests, quasistatic cyclic shear wall tests, and shake-table tests under four different ground motions scaled to design earthquake (DE)- and maximum considered earthquake (MCE)-level intensities. A generic shear connector was used for this study to allow for proprietary and other systems to demonstrate equivalence. The connectors were tested under shear and uplift, and shear-wall tests were performed using the Consortium of Universities for Research in Earthquake Engineering (CUREE) displacement protocol, which has been widely used for light-frame wood structures. Interstory drift (ISD) ratios in the shake-table tests ranged from 0.97% to 2.02%, and the tests demonstrated the system's ability to resist seismic loading. An FE model of the CLT wall was developed that showed good agreement with the cyclic and shake-table tests. The difference between the ISD ratios in the numerical model and the shake-table tests ranged from 5.4% to 31.3%, with an average of 17.9%, which was in good accordance with the accuracy of the existing CLT models. This system can be utilized as a retrofit option, in conjunction with light-frame wood shear walls, where lack of space may be a challenge.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270926
    Collections
    • Journal of Architectural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV