    Dynamic Effect of Tie-Bar Failure on Through Tied Arch Bridge

    Thumbnail
    View/Open
    %28ASCE%29CF.1943-5509.0001492.pdf (1.211Mb)
    Date
    10/1/2020
    Author
    Bing-hui Fan
    Su-guo Wang
    Bao-chun Chen
    Metadata
    Show full item record
    Abstract
    Tie bars on through tied arch bridges are often in poor condition and may serve as an external cause of a tie-bar failure accident; nevertheless, bridge structural robustness contributes greatly in resisting progressive collapse, and poor robustness tends to be the essential internal cause of possible accident. To study the dynamic effect of tie-bar failure of a through tied arch bridge and to reveal the mechanism of how structural robustness reduces dynamic effects, a finite-element model of a typical rigid-frame through tied arch bridge is developed based on the most adverse tie-bar breaking time, a transient-unloading method with equivalent load is adopted to analyze the dynamic response of tie-bar failure, and the results under different working conditions are compared. Furthermore, parameter analysis of the arch-to-pier stiffness ratio is conducted for the dynamic-amplification effect. The results indicate that both the pier and the arch rib have significant dynamic-amplification effects with respect to tie-bar breakage, and the remaining tie bars are the most vulnerable elements of the bridge; thus, they should be considered the most important elements when conducting tie-bar failure analysis; the most adverse breaking time adopted in cable breakage analysis can be taken as 0.01  T; a greater arch-to-pier stiffness ratio is beneficial to reduce the dynamic response brought on by tie-bar breakage; therefore, a rigid-frame through tied arch bridge should be designed with a large pier thrust stiffness, while a simply supported tied arch bridge should not be used in future through arch bridges, and existing ones should be retrofitted as soon as possible.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4268224
    Collections
    • Journal of Performance of Constructed Facilities

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV