    Enhanced Seismic Performance of Timber Structures Using Resilient Connections: Full-Scale Testing and Design Procedure

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002749.pdf (3.402Mb)
    Date
    9/1/2020 1
    Author
    Ashkan Hashemi
    Hamed Bagheri
    Seyed Mohammad Mahdi Yousef-Beik
    Farhad Mohammadi Darani
    Armin Valadbeigi
    Pouyan Zarnani
    Pierre Quenneville
    Metadata
    Show full item record
    Abstract
    The innovative resilient slip friction joint (RSFJ) technology has recently been developed and introduced to the construction industry. This technology not only aims to provide life safety for the occupants, but also to reduce earthquake-induced damage so the building can be reoccupied after an earthquake with minimum business disruption. While the seismic behavior of the conventional timber structures may be acceptable, previous research showed they have significant shortcomings such as irrecoverable inelastic damage in the fasteners, high response accelerations, and possible residual displacements. This paper presents dynamic component test results on these joints to investigate their performance under rapid load cycles. In addition, experimental results related to full-scale bidirectional testing of a rocking laminated veneer lumber (LVL) panel with RSFJ hold-downs are presented. Furthermore, a progressive step-by-step analysis and preliminary design procedure for structures using this technology is proposed that is based on the use of force-based design principle. Accordingly, a numerical model for a 5-story timber structure was developed and then the proposed procedure was applied to the model to design the connectors. Then the model was subjected to nonlinear static pushover and nonlinear dynamic time–history simulations to investigate the seismic performance of the structure. Finally, the performance of the case study structure was compared with a similar structure with the RSFJs replaced with conventional friction dampers. The findings of this research demonstrate that the proposed system has the potential to be considered as an efficient resilient seismic solution for timber structures and the presented design procedure can potentially be used for preliminary design of buildings with RSFJs.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4267656
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV