• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Seismic Performance Factors for Cross-Laminated Timber Shear Wall Systems in the United States

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002718.pdf (3.320Mb)
    Date
    9/1/2020 1
    Author
    John W. van de Lindt
    M. Omar Amini
    Douglas Rammer
    Philip Line
    Shiling Pei
    Marjan Popovski
    Metadata
    Show full item record
    Abstract
    Seismic force resisting systems based on cross-laminated timber (CLT) shear walls have garnered considerable attention for in mid-rise construction around the world. The purpose of this study was to determine seismic performance factors for CLT shear wall systems in platform type construction. These factors, namely, the response modification factors, R, overstrength factor, Ωo and deflection amplification factor, Cd, have been developed in this study for CLT walls and proposed for inclusion in ASCE 7. The study follows the FEMA P695 methodology that incorporates testing, evaluating a design methodology, defining the design space representative of typical construction, and comprehensive performance evaluation. The testing phase of the project consisted of connector testing and CLT shear wall testing, all with nonproprietary generic connectors to facilitate building code recognition. The design methodology and archetype development process are also discussed in this paper. A total of nine index buildings were developed from which 72 archetypes were extracted for this study. The archetypes were designed based on the design methodology and assessed with nonlinear pushover analysis and incremental dynamic analysis. Based on the required collapse margin, an R factor of 3 is proposed for CLT shear wall systems with 2∶1 or mixed aspect ratio panels up to 4∶1, and an R factor of 4 is proposed for CLT shear wall systems made up of only 4∶1 aspect ratio panels.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4267624
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV