    Variations of Stratification and Cooling Energy Performance According to Diffuser Condition in UFAD System

    Thumbnail
    View/Open
    %28ASCE%29EY.1943-7897.0000663.pdf (2.211Mb)
    Date
    2020
    Author
    Sang Hun Yeon
    Byeongho Yu
    Jong Man Lee
    Sung Lok Do
    Minjae Shin
    Kwang Ho Lee
    Metadata
    Show full item record
    Abstract
    The underfloor air distribution (UFAD) system, which is a building energy-saving technology, is an air-conditioning system that enables maintenance of the indoor temperature with a relatively low supply air flow rate. UFAD has advantages compared to the conventional overhead system, which improves occupants’ comfort, health, and work efficiency, decreases life cycle cost, and improves indoor air quality, ventilation efficiency, and lay-out flexibility related to building services. Also, the floor height is reduced because a duct is unnecessary. The stratification of the UFAD system is a key factor to the system, which refers to the inconsistent vertical temperature distribution from the floor to the ceiling due to the buoyant effect of air. It plays a critical role in determining the thermal, ventilation, and energy performance. However, based on the comprehensive literature review, study on the stratification of UFAD is insufficient due to lack of understanding and actual measurement facilities related to UFAD. Therefore, this study, by using the EnergyPlus simulation and phi-gamma formula, aims to assess the stratification according to the variation of a diffuser condition. As a result, stratification of the perimeter zone was improved by diffuser condition but the energy savings was not noticeable. The floor area of the interior zone accounts for 75% of the total floor area but stratification of the interior zone was not nearly changed by diffuser condition. Also, as the stratification was improved, the wall convection heat gain increased in the interior zone. Therefore, it is considered that the cooling load was increased and the decrease of energy consumption is insignificant.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4265556
    Collections
    • Journal of Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV