Show simple item record

dc.contributor.authorTaherian, S.
dc.contributor.authorRahai, H. R.
dc.contributor.authorBonifacio, J.
dc.contributor.authorGomez, B. Z.
dc.contributor.authorWaddington, Thomas
dc.date.accessioned2019-03-17T10:16:09Z
dc.date.available2019-03-17T10:16:09Z
dc.date.copyright11/14/2017 12:00:00 AM
dc.date.issued2019
dc.identifier.issn2572-7958
dc.identifier.otherjesmdt_001_01_011005.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256034
dc.description.abstractThe presence of obstructions such as tracheal stenosis has important effects on respiratory functions. Tracheal stenosis impacts the therapeutic efficacy of inhaled medications as a result of alterations in particle transport and deposition pattern. This study explores the effects of the presence and absence of stenosis/obstruction in the trachea on air flow characteristics and particle depositions. Computational fluid dynamics (CFD) simulations were performed on three-dimensional (3D) patient-specific models created from computed tomography (CT) images. The analyzed model was generated from a subject with tracheal stenosis and includes the airway tree up to eight generations. CT scans of expiratory and inspiratory phases were used for patient-specific boundary conditions. Pre- and post-intervention CFD simulations' comparison reveals the effect of the stenosis on the characteristics of air flow, transport, and depositions of particles with diameters of 1, 2.5, 4, 6, 8, and 10 μm. Results indicate that the existence of the stenosis inflicts a major pressure force on the flow of inhaled air, leading to an increased deposition of particles both above and below the stenosis. Comparisons of the decrease in pressure in each generation between pre- and post-tracheal stenosis intervention demonstrated a significant reduction in pressure following the stenosis, which was maintained in all downstream generations. Good agreements were found using experimental validation of CFD findings with a model of the control subject up to the third generation, constructed via additive layer manufacturing from CT images.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleParticulate Deposition in a Patient With Tracheal Stenosis
dc.typeJournal Paper
dc.journal.volume1
dc.journal.issue1
dc.journal.titleJournal of Engineering and Science in Medical Diagnostics and Therapy
dc.identifier.doi10.1115/1.4038260
dc.journal.fristpage11005
dc.journal.lastpage011005-10
dc.treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 001 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record