    Particulate Deposition in a Patient With Tracheal Stenosis

    Thumbnail
    View/Open
    jesmdt_001_01_011005.pdf (2.328Mb)
    Date
    2019
    Author
    Taherian, S.
    Rahai, H. R.
    Bonifacio, J.
    Gomez, B. Z.
    Waddington, Thomas
    Metadata
    Show full item record
    Abstract
    The presence of obstructions such as tracheal stenosis has important effects on respiratory functions. Tracheal stenosis impacts the therapeutic efficacy of inhaled medications as a result of alterations in particle transport and deposition pattern. This study explores the effects of the presence and absence of stenosis/obstruction in the trachea on air flow characteristics and particle depositions. Computational fluid dynamics (CFD) simulations were performed on three-dimensional (3D) patient-specific models created from computed tomography (CT) images. The analyzed model was generated from a subject with tracheal stenosis and includes the airway tree up to eight generations. CT scans of expiratory and inspiratory phases were used for patient-specific boundary conditions. Pre- and post-intervention CFD simulations' comparison reveals the effect of the stenosis on the characteristics of air flow, transport, and depositions of particles with diameters of 1, 2.5, 4, 6, 8, and 10 μm. Results indicate that the existence of the stenosis inflicts a major pressure force on the flow of inhaled air, leading to an increased deposition of particles both above and below the stenosis. Comparisons of the decrease in pressure in each generation between pre- and post-tracheal stenosis intervention demonstrated a significant reduction in pressure following the stenosis, which was maintained in all downstream generations. Good agreements were found using experimental validation of CFD findings with a model of the control subject up to the third generation, constructed via additive layer manufacturing from CT images.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4256034
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV