• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Testing of a Replaceable Brace Module for Seismically Designed Concentrically Braced Steel Frames

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002283.pdf (1.223Mb)
    Date
    2019
    Author
    Daniel Stevens; Lydell Wiebe
    Metadata
    Show full item record
    Abstract
    For a seismically designed concentrically braced frame with hollow structural sections as braces, the typical connection design consists of a slotted brace that is field welded to a gusset plate. During an earthquake, the brace is expected to buckle out-of-plane and the gusset plate is expected to yield. This makes it difficult to repair or replace the brace and connection, and the out-of-plane brace buckling caused by this connection can also damage surrounding walls and cladding, with potential life safety implications. This paper proposes an alternative connection that is expected to result in reduced erection costs by avoiding site welding, and also to simplify structural repairs following a major earthquake by confining all damage to a replaceable brace module. Additionally, the new connection causes the brace to buckle in-plane during a seismic event, reducing the potential for damage to the surrounding walls and cladding. This paper discusses large-scale quasi-static cyclic testing of eight brace modules with two variations of the new connection, one with a single-shear eccentric splice and the other with a double-sided concentric splice. All tested specimens had the desired failure progression and buckled in-plane, as intended. Bolt slip in the connection had very little effect on the overall force-deflection response after the brace compressive strength degraded to less than the slip load. The brace module was replaced after each test without observable damage outside the module. Although both connection variations behaved in a desirable manner, the single-shear eccentric splice was preferred because of the simpler constructability and improved performance.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4254310
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV