• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Forced and Mixed Convection Heat Transfer at High Pressure and High Temperature in a Graphite Flow Channel

    Thumbnail
    View/Open
    ht_140_12_122502.pdf (1.295Mb)
    Date
    2018
    Author
    Valentín, Francisco I.
    Artoun, Narbeh
    Kawaji, Masahiro
    McEligot, Donald M.
    Metadata
    Show full item record
    Abstract
    High pressure/high temperature forced and mixed convection experiments have been performed with helium and nitrogen at temperatures and pressures up to 893 K and 64 bar, respectively. The test section had a 16.8 mm ID flow channel in a 108 mm OD graphite column. Flow regimes included turbulent, transitional, and laminar flows with the inlet Reynolds numbers ranging from 1500 to 15,000. Due to strong heating, the local Reynolds number decreased by up to 50% over the 2.7 m test section. In addition, heat transfer degradation and flow laminarization caused by intense heating led to Nusselt numbers 20–50% lower than the values given by the modified Dittus–Boelter and modified Gnielinski correlations. Flow laminarization criteria were considered based on a dimensionless acceleration parameter (Kv) and buoyancy parameter (Bo*). Upward turbulent flows displayed higher wall temperatures than downward flows, due to the impact of flow laminarization which is not expected to affect buoyancy-opposed flows. Laminar Reynolds number flows presented an opposite behavior due to the enhancement of heat transfer for buoyancy-aided flows. At low Reynolds numbers, downward flows displayed higher and lower wall temperatures in the upstream and downstream regions, respectively, than the upward flow cases. In the entrance region of downward flows, convection heat transfer was reduced due to buoyancy leading to higher wall temperatures, while in the downstream region, buoyancy-induced mixing caused higher convection heat transfer and lower wall temperatures.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251859
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV