• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Water Resources Planning and Management
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Water Resources Planning and Management
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Locating Inadvertently Partially Closed Valves in Water Distribution Systems

    Thumbnail
    View/Open
    %28ASCE%29WR.1943-5452.0000958.pdf (1.075Mb)
    Date
    2018
    Author
    Do Nhu C.;Simpson Angus R.;Deuerlein Jochen W.;Piller Olivier
    Metadata
    Show full item record
    Abstract
    The reliability of a water distribution system is highly dependent on the management of its pipeline network. A pipe or a portion of the network can be isolated for inspection, maintenance, and replacement by the installation of isolation valves along the pipelines. However, the presence of isolation valves may cause a large discrepancy in the hydraulic behavior between the real system and results from a simulation model if the statuses of some of the valves in the system are unknown. Possible problems related to these valves are missing valves in the model due to poor or nonexistent documentation, errors in data transfer, or valve mechanical failure. This paper introduces an innovative methodology for the identification of unknown partially/fully closed valves in a water distribution network. An optimization problem is formulated for the unknown valve issue and solved by application of three sequentially applied methods, which include a local sensitivity analysis, an application of genetic algorithms (GAs), and an application of the Levenberg-Marquardt algorithm. In the first method, the sensitivity of the flow rates and nodal heads at measurement locations with respect to the change in the minor losses of the valves is computed. This computation is used to identify the valves that are unable to be localized by the measurement data. The second method applies a genetic algorithm combined with an extended period simulation in order to preliminarily identify the locations of the partially/fully closed valves and their setting values, i.e., the degree of opening of the valve. Finally, the application of the Levenberg-Marquardt (LM) algorithm was implemented to correct the results from the GA model. Results and discussions from two case studies show that the proposed methodologies can solve real-world problems.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4248149
    Collections
    • Journal of Water Resources Planning and Management

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV