• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effects of Diameter on the Durability of Glass Fiber–Reinforced Polymer Bars Conditioned in Alkaline Solution

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0000814.pdf (1.028Mb)
    Date
    2017
    Author
    Brahim Benmokrane
    Allan Manalo
    Jean-Charles Bouhet
    Khaled Mohamed
    Mathieu Robert
    Metadata
    Show full item record
    Abstract
    Current standards do not consider the diameter of glass fiber-reinforced polymer (GFRP) bars used as internal reinforcement in concrete structures to be a factor influencing bar durability. This paper investigates the effects of bar diameter on the physical and mechanical properties as well as the durability of GFRP reinforcing bars conditioned for three months at 60°C in an alkaline solution simulating a concrete environment. Five diameters (nominal diameters of 9.5, 12.7, 15.9, 19.1, and 25.4 mm) were considered; bar properties were assessed before and after conditioning. Microstructural analyses and measurement of physicochemical properties were also carried out. The results show that bar size had no significant effect on bar physical properties, except for water absorption. The smaller diameter bars had higher water absorption than the larger ones because of their higher surface area-to-volume ratios. In the case of the unconditioned bars, the tensile strength and modulus were not significantly affected by bar diameter, but there was a size effect for interlaminar shear strength and flexural strength. Conversely, the conditioning in the alkaline solution had a greater negative effect on the tensile strength of the larger bars than on the smaller ones. Scanning electron microscope (SEM) observations and Fourier transform infrared spectroscopy (FTIR) analysis revealed that the degradation remained at the surface of all the conditioned specimens. Nevertheless, there were only small variations between the physical and mechanical properties of the GFRP bars of different diameters. This indicates that the current provisions in standards that do not relate strength retention limit to bar size are acceptable.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4245422
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV