• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Bond of NSM FRP-Strengthened Concrete: Round Robin Test Initiative

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0000579.pdf (23.13Mb)
    Date
    2016
    Author
    Antonio Bilotta
    Francesca Ceroni
    Joaquim A. O. Barros
    Inês Costa
    Aniello Palmieri
    Zsombor K. Szabó
    Emidio Nigro
    Stijn Matthys
    György L. Balazs
    Marisa Pecce
    Metadata
    Show full item record
    Abstract
    Despite the extensive research on the debonding behavior of fiber-reinforced polymer (FRP) strengthening systems, no standard methodology has been established on its experimental characterization. To assess the performance and reliability of small-scale testing on near-surface mounted (NSM) FRP strengthening systems, an experimental program was carried out on a series of nine NSM FRP strengthening systems (bars and strips), in the framework of an international round robin testing (RRT). Eleven laboratories and seven manufacturers and suppliers participated in this extensive international exercise, which regarded both NSM and EBR FRP strengthening systems. The experimental results are discussed and compared in this paper in order to investigate (1) the bond behavior of NSM strips and bars, (2) the influence of alternative single-bond or double-bond shear pulling setups adopted by the participating laboratories, and (3) the influence in concrete strength due to different constituent materials between countries in applying a prescribed mix. The results show no significant influence of the concrete strength on both failure modes and loads. On the other hand, axial stiffness and surface treatment of the FRP NSM systems strongly affect both the bond strength and the parameters identifying the bond laws. Differences of bond strength experimentally recorded for the same FRP NSM systems tested according to different setups range between 10 and 25%. Therefore, for standard bond test protocol, the single shear bond test setup is more reliable, due to its higher feasibility compared with the double shear test setup.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4245296
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV