Full-Scale Tests and Numerical Analysis of Low-Rise CLT Structures under Lateral Loading
Date
2016Author
Motoi Yasumura
Kenji Kobayashi
Minoru Okabe
Tatsuya Miyake
Kazuyuki Matsumoto
Metadata
Show full item recordAbstract
This study examines the mechanical performance of large and small cross-laminated timber (CLT) wall panels with different applications. Two CLT structures were subjected to reversed cyclic lateral loads. One structure consisted of 90-mm-thick, large CLT wall panels (6×2.7 m), and the other consisted of 90-mm-thick, small CLT wall panels (1×2.7 m). A weight was installed on the roof of two-story structures to simulate the weight of three-story structures, designed by elastic calculations with a base shear coefficient of 1.0. The number of screws for each joint was determined by a linear finite-element method (FEM) analysis. The experimental results showed that the ultimate capacity of these structures is 60–80% higher than the design load, indicating high structural performance. A three-dimensional, nonlinear analysis was conducted via the FEM, which accurately predicted the mechanical performance of the CLT structures. This design procedure, based on linear analysis, resulted in a conservative design, and simulation using the nonlinear FEM provided an effective tool for design optimization.