dc.contributor.authorGowid, Samer
dc.contributor.authorDixon, Roger
dc.contributor.authorGhani, Saud
dc.date.accessioned2017-11-25T07:20:46Z
dc.date.available2017-11-25T07:20:46Z
dc.date.copyright2017/13/4
dc.date.issued2017
dc.identifier.issn0022-0434
dc.identifier.otherds_139_06_061013.pdf
dc.identifier.urihttp://138.201.223.254:8080/yetl1/handle/yetl/4236653
dc.description.abstractThis paper compares and evaluates the performance of two major feature selection and fault identification methods utilized for the condition monitoring (CM) of centrifugal equipment, namely fast Fourier transform (FFT)-based segmentation, feature selection, and fault identification (FS2FI) algorithm and neural network (NN). Multilayer perceptron (MLP) is the most commonly used NN model for fault pattern recognition. Feature selection and trending play an important role in pattern recognition and hence affect the performance of CM systems. The technical and developmental challenges of both methods were investigated experimentally on a Paxton industrial centrifugal air blower system with a rotational speed of 15,650 RPMs. Five different machine conditions were experimentally emulated in the laboratory. A low training-to-testing ratio of 50% was utilized to evaluate the performance of both methods. In order to maximize fault identification accuracy and minimize computing time and cost, a near-optimal NN configuration was identified. The results showed that both techniques operated with a fault identification accuracy of 100%. However, the FS2FI algorithm showed a number of advantages over NN. These advantages include the ease of implementation and a reduction of cost and time in development and computing, as it processed the data from the first trial in less than 6.2% of the time taken by the NN.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePerformance Comparison Between Fast Fourier Transform-Based Segmentation, Feature Selection, and Fault Identification Algorithm and Neural Network for the Condition Monitoring of Centrifugal Equipment
dc.typeJournal Paper
dc.journal.volume139
dc.journal.issue6
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.4035458
dc.journal.fristpage61013
dc.journal.lastpage061013-9
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2017:;volume( 139 ):;issue: 006