    Performance Comparison Between Fast Fourier Transform-Based Segmentation, Feature Selection, and Fault Identification Algorithm and Neural Network for the Condition Monitoring of Centrifugal Equipment

    Thumbnail
    View/Open
    ds_139_06_061013.pdf (2.055Mb)
    Date
    2017
    Author
    Gowid, Samer
    Dixon, Roger
    Ghani, Saud
    Metadata
    Show full item record
    Abstract
    This paper compares and evaluates the performance of two major feature selection and fault identification methods utilized for the condition monitoring (CM) of centrifugal equipment, namely fast Fourier transform (FFT)-based segmentation, feature selection, and fault identification (FS2FI) algorithm and neural network (NN). Multilayer perceptron (MLP) is the most commonly used NN model for fault pattern recognition. Feature selection and trending play an important role in pattern recognition and hence affect the performance of CM systems. The technical and developmental challenges of both methods were investigated experimentally on a Paxton industrial centrifugal air blower system with a rotational speed of 15,650 RPMs. Five different machine conditions were experimentally emulated in the laboratory. A low training-to-testing ratio of 50% was utilized to evaluate the performance of both methods. In order to maximize fault identification accuracy and minimize computing time and cost, a near-optimal NN configuration was identified. The results showed that both techniques operated with a fault identification accuracy of 100%. However, the FS2FI algorithm showed a number of advantages over NN. These advantages include the ease of implementation and a reduction of cost and time in development and computing, as it processed the data from the first trial in less than 6.2% of the time taken by the NN.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4236653
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV