    Optimization for Steam Turbine Cold-End System of a Nuclear Power Plant and Sensitivity Analysis

    Thumbnail
    View/Open
    ners_3_1_014501.pdf (491.7Kb)
    Date
    2017
    Author
    Yang, Jia
    Zhang, Rongyong
    Metadata
    Show full item record
    Abstract
    This article conducts optimization and sensitivity analysis for the cold-end system of a nuclear power plant (NPP) with a sea water circulating system, using the minimum annual cost method by dynamic economical analysis. The following factors are taken into account for the optimization: the design of a condenser (cooling area and the parameters of cooling tubes), the scale of the cooling tower, the flow rate of circulation water, and the diameter of circulating pipes. In conclusion, the optimum scheme of the cold-end system is obtained for the double-back pressure turbine project. The variation trend of the annual cost with changing circulating water amount is also concluded. Finally, this article provides the sensitivity analysis of the feed-in tariff.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4235420
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV