Show simple item record

dc.contributor.authorRicardo A. Herrera
dc.contributor.authorJames M. Ricles
dc.contributor.authorRichard Sause
dc.date.accessioned2017-05-08T21:00:28Z
dc.date.available2017-05-08T21:00:28Z
dc.date.copyrightFebruary 2008
dc.date.issued2008
dc.identifier.other%28asce%290733-9445%282008%29134%3A2%28279%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/35182
dc.description.abstractThe seismic performance of a composite moment resisting frame (MRF) comprised of concrete filled tube (CFT) columns and wide flange beams was investigated experimentally. The four-story composite MRF test structure was designed using performance-based design concepts. The performance objectives include achieving: (1) the operational performance level under the frequent occurrence earthquake; (2) the life safety performance level under the design basis earthquake; and (3) the collapse prevention performance level under the maximum considered earthquake. The hybrid pseudodynamic test method was used to subject the test structure to these various seismic input levels.
dc.publisherAmerican Society of Civil Engineers
dc.titleSeismic Performance Evaluation of a Large-Scale Composite MRF Using Pseudodynamic Testing
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue2
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)0733-9445(2008)134:2(279)
dc.treeJournal of Structural Engineering:;2008:;Volume ( 134 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record