Seismic Performance Evaluation of a Large-Scale Composite MRF Using Pseudodynamic Testing
Abstract
The seismic performance of a composite moment resisting frame (MRF) comprised of concrete filled tube (CFT) columns and wide flange beams was investigated experimentally. The four-story composite MRF test structure was designed using performance-based design concepts. The performance objectives include achieving: (1) the operational performance level under the frequent occurrence earthquake; (2) the life safety performance level under the design basis earthquake; and (3) the collapse prevention performance level under the maximum considered earthquake. The hybrid pseudodynamic test method was used to subject the test structure to these various seismic input levels.