Flaw Stability Considering Residual Stress for Aging Management of Spent Nuclear Fuel Multiple Purpose Canisters
Abstract
A typical multipurpose canister (MPC) is made of austenitic stainless steel and is loaded with spent nuclear fuel (SNF) assemblies. Because heat treatment for stress relief is not required for the construction of the MPC, the canister is susceptible to stress corrosion cracking in the weld or heat affected zone (HAZ) regions under longterm storage conditions. Logic for flaw acceptance is developed should cracklike flaws be detected by Inservice Inspection. The procedure recommended by API 5791/ASME FFS1, FitnessforService, is used to calculate the instability crack length or depth by failure assessment diagram (FAD). It is demonstrated that the welding residual stress (RS) has a strong influence on the results.