Show simple item record

dc.contributor.authorBighamian, Ramin
dc.contributor.authorKim, Chang
dc.contributor.authorReisner, Andrew T.
dc.contributor.authorHahn, Jin
dc.date.accessioned2017-05-09T01:27:17Z
dc.date.available2017-05-09T01:27:17Z
dc.date.issued2016
dc.identifier.issn0022-0434
dc.identifier.otherds_138_11_111005.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/160751
dc.description.abstractThis paper presents a closedloop control of fluid resuscitation to overcome hypovolemia based on modelbased estimation of relative changes in blood volume (BV). In this approach, the control system consists of a modelbased relative BV (RBV) estimator and a feedback controller. The former predicts relative changes in the BV response to augmented fluid by analyzing an arterial blood pressure (BP) waveform and the electrocardiogram (ECG). Then, the latter determines the amount of fluid to be augmented by comparing target versus predicted relative changes in BV. In this way, unlike many previous methods for fluid resuscitation based on controlled variable(s) nonlinearly correlated with the changes in BV, fluid resuscitation can be guided by a controlled variable linearly correlated with the changes in BV. This paper reports initial design of the closedloop fluid resuscitation system and its in silico evaluation in a wide range of hypovolemic scenarios. The results suggest that closedloop fluid resuscitation guided by a controlled variable linearly correlated with the changes in BV can be effective in overcoming hypovolemia: across 100 randomly produced hypovolemia cases, it resulted in the BV regulation error of 7.98 آ±â€‰171.6 ml, amounting to 0.18 آ±â€‰3.04% of the underlying BV. When guided by pulse pressure (PP), a classical controlled variable nonlinearly correlated with the changes in BV; the same closedloop fluid resuscitation system resulted in persistent underresuscitation with the BV regulation error of −779.1 آ±â€‰147.4 ml, amounting to −13.9 آ±â€‰2.65% of the underlying BV.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleClosed Loop Fluid Resuscitation Control Via Blood Volume Estimation
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue11
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.4033833
dc.journal.fristpage111005
dc.journal.lastpage111005
dc.identifier.eissn1528-9028
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2016:;volume( 138 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record