    Closed Loop Fluid Resuscitation Control Via Blood Volume Estimation

    Thumbnail
    View/Open
    ds_138_11_111005.pdf (1.171Mb)
    Date
    2016
    Author
    Bighamian, Ramin
    Kim, Chang
    Reisner, Andrew T.
    Hahn, Jin
    Metadata
    Show full item record
    Abstract
    This paper presents a closedloop control of fluid resuscitation to overcome hypovolemia based on modelbased estimation of relative changes in blood volume (BV). In this approach, the control system consists of a modelbased relative BV (RBV) estimator and a feedback controller. The former predicts relative changes in the BV response to augmented fluid by analyzing an arterial blood pressure (BP) waveform and the electrocardiogram (ECG). Then, the latter determines the amount of fluid to be augmented by comparing target versus predicted relative changes in BV. In this way, unlike many previous methods for fluid resuscitation based on controlled variable(s) nonlinearly correlated with the changes in BV, fluid resuscitation can be guided by a controlled variable linearly correlated with the changes in BV. This paper reports initial design of the closedloop fluid resuscitation system and its in silico evaluation in a wide range of hypovolemic scenarios. The results suggest that closedloop fluid resuscitation guided by a controlled variable linearly correlated with the changes in BV can be effective in overcoming hypovolemia: across 100 randomly produced hypovolemia cases, it resulted in the BV regulation error of 7.98 آ±â€‰171.6 ml, amounting to 0.18 آ±â€‰3.04% of the underlying BV. When guided by pulse pressure (PP), a classical controlled variable nonlinearly correlated with the changes in BV; the same closedloop fluid resuscitation system resulted in persistent underresuscitation with the BV regulation error of −779.1 آ±â€‰147.4 ml, amounting to −13.9 آ±â€‰2.65% of the underlying BV.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/160751
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV