Effects of Pressure and a Microporous Coating on HFC 245fa Pool Boiling Heat Transfer
View/ Open
Date
2014Author
Moreno, Gilberto
Jeffers, Jana R.
Narumanchi, Sreekant
Metadata
Show full item recordAbstract
A study was conducted to experimentally characterize the pool boiling performance of hydrofluorocarbon HFC245fa at pressures ranging from 0.15 MPa to 1.1 MPa (reduced pressure range: 0.04–0.31). Pool boiling experiments were conducted using horizontally oriented 1cm2 heated surfaces to quantify the effects of pressure and a microporousenhanced coating on heat transfer coefficients and critical heat flux (CHF) values. Results showed that the coating enhanced heat transfer coefficients and CHF by 430% and 50%, respectively. The boiling heat transfer performance of HFC245fa was then compared with the boiling performance of HFC134a and hydrofluoroolefin HFO1234yf.