• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Pressure Vessel Technology
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Pressure Vessel Technology
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effect of Bolt Spacing on the Circumferential Distribution of the Gasket Contact Stress in Bolted Flange Joints

    Thumbnail
    View/Open
    JPVTAS-28548#041205_1.pdf (1.561Mb)
    Date
    2011
    Author
    Tan Dan Do
    Abdel-Hakim Bouzid
    Thien-My Dao
    Metadata
    Show full item record
    Abstract
    Bolted flange joints are part of pressure vessel and piping components and are extensively used in the chemical, petrochemical, and nuclear power industries. They are simple structures and offer the possibility of disassembly, which makes them attractive to connect pressurized equipment and piping. In addition to being prone to leakage, they often require maintenance while in operation in which case the bolts are either retightened as in hot torquing or untightened to be replaced. Although costly shutdowns are avoided, such maintenance work exposes the operator to a potential risk because the bolt load alteration can produce a gasket load unbalance, which results in the local gasket contact stress to drop below some critical value, causing major leak and hence jeopardizing the life of the worker. This paper addresses the issue of the contact stress level unbalance around the flange when the bolts are subjected to initial tightening. The study compares the contact stress distribution variations, an analytical developed model based on the theory of rings on elastic foundation, to those given by the finite element model and the simple beam on elastic foundation model developed by (2007, “Flange Joint Bolt Spacing Requirements,” Proceedings of PVP2007, ASME Pressure Vessel and Piping Division Conference ). This study is developed for the purpose of helping limit the degree of load increase in hot torquing or the maximum number of bolts to be replaced at a time and identify those flanges for which the bolt cannot be replaced in service.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/147447
    Collections
    • Journal of Pressure Vessel Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV