    Heat Transfer Experiments in a Confined Jet Impingement Configuration Using Transient Techniques

    Thumbnail
    View/Open
    JHTRAO-27922#091601_1.pdf (2.527Mb)
    Date
    2011
    Author
    Florian Hoefler
    Nils Dietrich
    Jens Wolfersdorf
    Metadata
    Show full item record
    Abstract
    A confined jet impingement configuration has been investigated in which the matter of interest is the convective heat transfer from the air flow to the passage walls. The geometry is similar to gas turbine blade cooling applications. The setup is distinct from usual cooling passages by the fact that no crossflow and no bulk flow directions are present. The flow exhausts through two staggered rows of holes opposing the impingement wall. Hence, a complex 3-D vortex system arises, which entails a complex heat transfer situation. The transient thermochromic liquid crystal (TLC) method was used in previous studies to measure the heat transfer on the passage walls. Due to the nature of these experiments, the fluid as well as the wall temperature vary with location and time. As a prerequisite of the transient TLC technique, the heat transfer coefficient is assumed to be constant over the transient experiment. Therefore, it is the scope of this article to qualify this assumption and to validate the results at discrete locations. For this purpose, fast response surface thermocouples and heat flux sensors were applied, in order to gain information on the temporal evolution of the wall heat fluxes. The linear relation between heat flux and temperature difference could be verified for all measurement sites. This validates the assumption of a constant heat transfer coefficient. Nusselt number evaluations from independent techniques show a good agreement, considering the respective uncertainty ranges. For all investigated sites, the Nusselt numbers range within ±9% of the values gained from the TLC measurement.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/146603
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV