dc.description.abstractPower supply is an important aspect of micronanobiomedical devices. Implantable devices are required to stay inside of the body for longer period of time to provide continuous monitoring, detection, and therapeutics. The constricted areas of the human body, accessed by these devices, imply that the power source should not increase the payload significantly. Conventional on-board power sources are big, as compared with the device themselves, or involve wire-outs. Both provisions are liable to develop complications for sensor/actuator implant packaging. A plausible approach can be innovative solutions for sustainable bio-energy harvesting. Research studies have reported feasibility of miniature power sources, running on redox reactions. The device design, reported in this study, is a combination of nano-engineered composites and flexible thin film processing to achieve high density packaging. Of which, the end goal is production of energy for sensor applications. Both the bio-electrodes were successfully functionalized by amide bond cross-linkage between the carbon nanotube surface and the enzyme molecules: catalase and glucose oxidase for cathode and anode, respectively. The nanocomposite based biopower cell was evaluated as a steady power supply across the physiological range of glucose concentration. The power cell was able to deliver a steady power of 3.2 nW at 85 mV for glucose concentrations between 3 mM and 8 mM. Electron microscopy scanning of the functionalized electrode surface and spectroscopic evaluation of nanotube surface were used for evaluation of the biofunctionalization technique. Cyclic voltametric (CV) scans were performed on the cathodic and anodic half cells to corroborate bioactivity and qualitatively evaluate the power cell output against the redox peaks on the CV scans. The importance of these results has been discussed and conclusions have been drawn pertaining to further miniaturization (scale down) of the cell.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleGlucose Driven Nanobiopower Cells for Biomedical Applications
dc.typeJournal Paper
dc.journal.volume1
dc.journal.issue2
dc.journal.titleJournal of Nanotechnology in Engineering and Medicine
dc.identifier.doi10.1115/1.4001494
dc.journal.fristpage21009
dc.identifier.eissn1949-2952
dc.keywordsAnodes
dc.keywordsComposite materials
dc.keywordsSensors
dc.keywordsElectrodes
dc.keywordsCarbon nanotubes
dc.keywordsEnzymes
dc.keywordsOxygen
dc.keywordsPhysiology
dc.keywordsBiomedicine
dc.keywordsElectric potential
dc.keywordsDensity
dc.keywordsDesign
dc.keywordsNanocomposites
dc.keywordsLinkages
dc.keywordsPackaging
dc.keywordsoxidation AND Electron transport
dc.treeJournal of Nanotechnology in Engineering and Medicine:;2010:;volume( 001 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record