• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Nanotechnology in Engineering and Medicine
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Nanotechnology in Engineering and Medicine
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Glucose Driven Nanobiopower Cells for Biomedical Applications

    Thumbnail
    View/Open
    JNEMAA-28035#021009_1.pdf (505.2Kb)
    Date
    2010
    Author
    Pratyush Rai
    Thang Ho
    Jining Xie
    Jamie A. Hestekin
    Vijay K. Varadan
    Metadata
    Show full item record
    Abstract
    Power supply is an important aspect of micronanobiomedical devices. Implantable devices are required to stay inside of the body for longer period of time to provide continuous monitoring, detection, and therapeutics. The constricted areas of the human body, accessed by these devices, imply that the power source should not increase the payload significantly. Conventional on-board power sources are big, as compared with the device themselves, or involve wire-outs. Both provisions are liable to develop complications for sensor/actuator implant packaging. A plausible approach can be innovative solutions for sustainable bio-energy harvesting. Research studies have reported feasibility of miniature power sources, running on redox reactions. The device design, reported in this study, is a combination of nano-engineered composites and flexible thin film processing to achieve high density packaging. Of which, the end goal is production of energy for sensor applications. Both the bio-electrodes were successfully functionalized by amide bond cross-linkage between the carbon nanotube surface and the enzyme molecules: catalase and glucose oxidase for cathode and anode, respectively. The nanocomposite based biopower cell was evaluated as a steady power supply across the physiological range of glucose concentration. The power cell was able to deliver a steady power of 3.2 nW at 85 mV for glucose concentrations between 3 mM and 8 mM. Electron microscopy scanning of the functionalized electrode surface and spectroscopic evaluation of nanotube surface were used for evaluation of the biofunctionalization technique. Cyclic voltametric (CV) scans were performed on the cathodic and anodic half cells to corroborate bioactivity and qualitatively evaluate the power cell output against the redox peaks on the CV scans. The importance of these results has been discussed and conclusions have been drawn pertaining to further miniaturization (scale down) of the cell.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/144550
    Collections
    • Journal of Nanotechnology in Engineering and Medicine

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV