Show simple item record

dc.contributor.authorB. Borgmeyer
dc.contributor.authorD. Jacobson
dc.contributor.authorD. Hussey
dc.contributor.authorC. Wilson
dc.contributor.authorR. A. Winholtz
dc.contributor.authorH. B. Ma
dc.date.accessioned2017-05-09T00:38:56Z
dc.date.available2017-05-09T00:38:56Z
dc.date.copyrightJune, 2010
dc.date.issued2010
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27889#061502_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/143840
dc.description.abstractAn experimental investigation into the parameters affecting heat transport in two three-dimensional oscillating heat pipes (OHPs) was implemented. A three-dimensional OHP is one in which the center axis of the circular channels containing the internal working fluid do not lie in the same plane. This novel design allows for more turns in a more compact size. The OHPs in the current investigation is made of copper tubings (3.175 mm outside diameter, 1.65 mm inside diameter) wrapped in a three-dimensional fashion around two copper spreaders that act as the evaporator and condenser. The two OHPs have 10 and 20 turns in both the evaporator and condenser. The 20-turn OHP was filled to 50% of the total volume with a high performance liquid chromatography grade water. Transient and steady state temperature data were recorded at different locations for various parameters. Parameters such as heat input, operating temperature, and filling ratio were varied to determine its effect on the overall heat transport. Neutron radiography was simultaneously implemented to create images of the internal working fluid flow at a rate of 30 frames per second. Results show the average temperature drop from the evaporator to condenser decreases at higher heat inputs due to an increase in temperature throughout the condenser region due to greater oscillations. These large oscillations were visually observed using neutron radiography. As the operating temperature is increased, the thermal resistance is reduced. A decrease in filling ratio tends to create more steady fluid motion; however, the heat transfer performance is reduced.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHeat Transport Capability and Fluid Flow Neutron Radiography of Three-Dimensional Oscillating Heat Pipes
dc.typeJournal Paper
dc.journal.volume132
dc.journal.issue6
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4000750
dc.journal.fristpage61502
dc.identifier.eissn1528-8943
dc.keywordsFluid dynamics
dc.keywordsHeat
dc.keywordsTemperature
dc.keywordsHeat pipes
dc.keywordsCondensers (steam plant)
dc.keywordsOperating temperature
dc.keywordsNeutron radiography
dc.keywordsFluids
dc.keywordsMotion
dc.keywordsHeat transfer
dc.keywordsOscillations
dc.keywordsDrops AND Channels (Hydraulic engineering)
dc.treeJournal of Heat Transfer:;2010:;volume( 132 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record