• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Heat Transport Capability and Fluid Flow Neutron Radiography of Three-Dimensional Oscillating Heat Pipes

    Thumbnail
    View/Open
    JHTRAO-27889#061502_1.pdf (949.6Kb)
    Date
    2010
    Author
    B. Borgmeyer
    D. Jacobson
    D. Hussey
    C. Wilson
    R. A. Winholtz
    H. B. Ma
    Metadata
    Show full item record
    Abstract
    An experimental investigation into the parameters affecting heat transport in two three-dimensional oscillating heat pipes (OHPs) was implemented. A three-dimensional OHP is one in which the center axis of the circular channels containing the internal working fluid do not lie in the same plane. This novel design allows for more turns in a more compact size. The OHPs in the current investigation is made of copper tubings (3.175 mm outside diameter, 1.65 mm inside diameter) wrapped in a three-dimensional fashion around two copper spreaders that act as the evaporator and condenser. The two OHPs have 10 and 20 turns in both the evaporator and condenser. The 20-turn OHP was filled to 50% of the total volume with a high performance liquid chromatography grade water. Transient and steady state temperature data were recorded at different locations for various parameters. Parameters such as heat input, operating temperature, and filling ratio were varied to determine its effect on the overall heat transport. Neutron radiography was simultaneously implemented to create images of the internal working fluid flow at a rate of 30 frames per second. Results show the average temperature drop from the evaporator to condenser decreases at higher heat inputs due to an increase in temperature throughout the condenser region due to greater oscillations. These large oscillations were visually observed using neutron radiography. As the operating temperature is increased, the thermal resistance is reduced. A decrease in filling ratio tends to create more steady fluid motion; however, the heat transfer performance is reduced.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/143840
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV