Show simple item record

dc.contributor.authorTimothy B. Roth
dc.contributor.authorAnn M. Anderson
dc.date.accessioned2017-05-09T00:29:16Z
dc.date.available2017-05-09T00:29:16Z
dc.date.copyrightJanuary, 2008
dc.date.issued2008
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27830#014503_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/138635
dc.description.abstractThis paper presents results from a study aimed at developing a novel thermochromic liquid crystal (TLC) temperature measurement system that uses light transmission instead of light reflection to measure surface temperature fields. In previous work, we reported on the effect of temperature on light transmission through TLCs as measured with a spectrophotometer [, and , 2005, “ Light Transmission Characteristics of Thermochromic Liquid Crystals,” Proceedings of IMECE2005, Orlando, FL, Paper No. IMECE2005-81812;, and , 2007, “ The Effects of Film Thickness, Light Polarization and Light Intensity on the Light Transmission Characteristics of Thermochromic Liquid Crystals,” ASME J. Heat Transfer, 129(3), pp. 372–378]. Here we report on results obtained using a charge coupled device (CCD) camera and polychromatic light setup that is similar to the type of equipment used in TLC reflection thermography. We tested three different light sources, a white electroluminescent light, a green electroluminescent light, and a halogen fiber optic light, using both direct and remote lighting techniques. We found that the green signal (as detected by the CCD camera) of the green electroluminescent light makes the best temperature sensor, because under remote lighting conditions it showed a 500% linear signal increase as the temperature of the R25C10W TLCs was raised from 30°to48°C. We further found that the angle of the CCD camera relative to the light did not significantly affect the results for angles up to 10deg for remote lighting and 15deg for direct lighting. The effect of light intensity variation was not significant for intensities up to 40% of the original level when normalized on the intensity at 19°C (a temperature outside the active range of the TLCs). The use of light transmission results in a larger range of temperature over which the TLCs can be calibrated and offers opportunities for more uniform lighting conditions, which may help overcome some of the problems associated with light reflection.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Light Transmission Based Liquid Crystal Thermography System
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue1
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.2780187
dc.journal.fristpage14503
dc.identifier.eissn1528-8943
dc.keywordsTemperature
dc.keywordsLiquid crystals
dc.keywordsThermography
dc.keywordsLight sources
dc.keywordsSignals
dc.keywordsUncertainty AND Light reflection
dc.treeJournal of Heat Transfer:;2008:;volume( 130 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record