Show simple item record

dc.contributor.authorRobert Cheesewright
dc.contributor.authorAli Belhadj
dc.contributor.authorColin Clark
dc.date.accessioned2017-05-09T00:09:49Z
dc.date.available2017-05-09T00:09:49Z
dc.date.copyrightMarch, 2003
dc.date.issued2003
dc.identifier.issn0022-0434
dc.identifier.otherJDSMAA-26314#103_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/128158
dc.description.abstractAn analytical study of the response of a simple Coriolis meter subjected to external mechanical vibrations and corresponding finite element studies of three commercially available meters are presented. These show that vibrations produce additional components in the meter sensor signals but that these components are only at the frequency of the vibrations. The results show that errors reported in vibration experiments, using any frequency except the meter drive frequency, are due to failure of the determination of the phase difference between the sensor signals. The results also show that external vibrations at the meter drive frequency produce a meter error regardless of the phase detection algorithm.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffect of Mechanical Vibrations on Coriolis Mass Flow Meters
dc.typeJournal Paper
dc.journal.volume125
dc.journal.issue1
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.1539098
dc.journal.fristpage103
dc.journal.lastpage113
dc.identifier.eissn1528-9028
dc.keywordsMotion
dc.keywordsVibration
dc.keywordsFlow (Dynamics)
dc.keywordsSensors
dc.keywordsSignals
dc.keywordsFinite element analysis AND Errors
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2003:;volume( 125 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record