    Effect of Mechanical Vibrations on Coriolis Mass Flow Meters

    Thumbnail
    View/Open
    JDSMAA-26314#103_1.pdf (174.3Kb)
    Date
    2003
    Author
    Robert Cheesewright
    Ali Belhadj
    Colin Clark
    Metadata
    Show full item record
    Abstract
    An analytical study of the response of a simple Coriolis meter subjected to external mechanical vibrations and corresponding finite element studies of three commercially available meters are presented. These show that vibrations produce additional components in the meter sensor signals but that these components are only at the frequency of the vibrations. The results show that errors reported in vibration experiments, using any frequency except the meter drive frequency, are due to failure of the determination of the phase difference between the sensor signals. The results also show that external vibrations at the meter drive frequency produce a meter error regardless of the phase detection algorithm.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/128158
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV