dc.description.abstractIn 1996, Code Case 2235, which allows ultrasonic examination of welds in lieu of radiography for ASME Section VIII Division 1 and Division 2 vessels, was approved by the ASME B&PV Code Committee. This Code Case has been revised to incorporate: 1) a reduction in minimum usable thickness from 4″ (107.6 mm) to 0.5″ (12.7 mm), and 2) flaw acceptance criteria including rules on multiple flaws. A linear elastic fracture mechanics procedure has been used in developing the flaw acceptance criteria. This paper presents the technical basis for Code Case 2235.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTechnical Basis for ASME Section VIII Code Case 2235 on Ultrasonic Examination of Welds in Lieu of Radiography
dc.typeJournal Paper
dc.journal.volume123
dc.journal.issue3
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.1376719
dc.journal.fristpage338
dc.journal.lastpage345
dc.identifier.eissn1528-8978
dc.keywordsWelded joints
dc.keywordsAcceptance criteria
dc.keywordsThickness
dc.keywordsVessels
dc.keywordsFracture (Process)
dc.keywordsSizing (Textile treatment)
dc.keywordsFracture mechanics AND Construction
dc.treeJournal of Pressure Vessel Technology:;2001:;volume( 123 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record