    Technical Basis for ASME Section VIII Code Case 2235 on Ultrasonic Examination of Welds in Lieu of Radiography

    Thumbnail
    View/Open
    JPVTAS-28410#338_1.pdf (188.2Kb)
    Date
    2001
    Author
    Mahendra D. Rana
    Owen Hedden
    Dave Cowfer
    Roger Boyce
    Metadata
    Show full item record
    Abstract
    In 1996, Code Case 2235, which allows ultrasonic examination of welds in lieu of radiography for ASME Section VIII Division 1 and Division 2 vessels, was approved by the ASME B&PV Code Committee. This Code Case has been revised to incorporate: 1) a reduction in minimum usable thickness from 4″ (107.6 mm) to 0.5″ (12.7 mm), and 2) flaw acceptance criteria including rules on multiple flaws. A linear elastic fracture mechanics procedure has been used in developing the flaw acceptance criteria. This paper presents the technical basis for Code Case 2235.