    Instantaneous Flow Rate Measurement of Ideal Gases

    Thumbnail
    View/Open
    JDSMAA-26262#174_1.pdf (96.78Kb)
    Date
    2000
    Author
    Kenji Kawashima
    Research Associate
    Toshiharu Kagawa
    Toshinori Fujita
    Research Associate
    Metadata
    Show full item record
    Abstract
    In this paper, a chamber called an “Isothermal Chamber” was developed. The isothermal chamber can almost realize isothermal condition due to larger heat transfer area and heat transfer coefficient by stuffing steel wool in it. Using this chamber, a simple method to measure flow rates of ideal gases was developed. As the process during charge or discharge is almost isothermal, instantaneous flow rates charged into or discharged from the chamber can be obtained measuring only pressure in the chamber. The steady and the unsteady flow rate of air were measured by the proposed method, and the effectiveness of the method was demonstrated. [S0022-0434(00)00301-4]
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/123510
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV