    Use of Subsized Specimen for Evaluating the Strength and Fracture Toughness of Irradiated 2 1/4 Cr-1 M0 Steel

    Thumbnail
    View/Open
    JEMTA8-26950#168_1.pdf (842.9Kb)
    Date
    1992
    Author
    X. Mao
    H. Takahashi
    T. Kodaira
    Metadata
    Show full item record
    Abstract
    The procedure of the determination of yield and ultimate strengths of irradiated 2 1/4 Cr-1 M0 steel using small punch specimen (10 mm by 10 mm by 0.5 mm) has been demonstrated. The result was compared with the result obtained from conventional tensile test. Fracture toughness of irradiated 2 1/4 Cr-1 M0 steel was measured by use of subsized CT specimen and D. C. electrical potential method. Owing to irradiation hardening of 2 1/4 Cr-1 M0 steel, yield and ultimate strength increase substantially and fracture toughness decreases 37 percent when the steel is irradiated to a fluence of 3.2 x 1023 n/m2 . The small punch and subsized CT specimen can be used for irradiation test so that considerable irradiation space will be saved.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/110336
    Collections
    • Journal of Engineering Materials and Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV