Show simple item record

contributor authorS. L. Collier
contributor authorC. C. Hoerner
date accessioned2017-05-08T23:15:20Z
date available2017-05-08T23:15:20Z
date copyrightMarch, 1983
date issued1983
identifier issn0195-0738
identifier otherJERTD2-26389#62_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/96992
description abstractThe important time for a check valve is the short period during which flow decelerates. The characteristics of this period are not well defined. The investigation suggests the use of deceleration (g) as a parameter, describes a test facility that provides a range of deceleration rates and presents results of tests at various g’s. This method couples the estimation of a system’s deceleration with the performance of the valve so that provisions can be made for the expected behavior and surge in a new installation or an improvement can be predicted for an existing problem situation.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Facility and Approach to Performance Test of Check Valves
typeJournal Paper
journal volume105
journal issue1
journal titleJournal of Energy Resources Technology
identifier doi10.1115/1.3230878
journal fristpage62
journal lastpage66
identifier eissn1528-8994
keywordsValves
keywordsTesting performance
keywordsFlow (Dynamics)
keywordsSurges AND Test facilities
treeJournal of Energy Resources Technology:;1983:;volume( 105 ):;issue: 001