Show simple item record

contributor authorJ. M. Kabo
contributor authorW. Goldsmith
contributor authorN. M. Harris
date accessioned2017-05-08T23:14:56Z
date available2017-05-08T23:14:56Z
date copyrightNovember, 1983
date issued1983
identifier issn0148-0731
identifier otherJBENDY-25754#316_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/96755
description abstractTwo unembalmed and one embalmed human cadaveric head-neck systems were instrumented and subjected to central forehead impact of ballistically suspended 3.07-kg aluminum shell at velocities ranging from 50 to 345 cm/s. Occipital skull accelerations and disk pressures were measured by transducers, while the deformation of the system was determined by framing camera data. The results were found to be in accord with those from corresponding tests in artifical head-neck replica. Initial and terminal X-ray examination of the structure revealed no evidence of either skull or vertebral fractures.
publisherThe American Society of Mechanical Engineers (ASME)
titleIn-Vitro Head and Neck Response to Impact
typeJournal Paper
journal volume105
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3138427
journal fristpage316
journal lastpage320
identifier eissn1528-8951
keywordsDeformation
keywordsX-rays
keywordsAluminum
keywordsStructural frames
keywordsTransducers
keywordsDisks
keywordsShells AND Spinal fractures
treeJournal of Biomechanical Engineering:;1983:;volume( 105 ):;issue: 004
contenttypeFulltext