Show simple item record

contributor authorHan C. Wu
contributor authorT. P. Wang
date accessioned2017-05-08T23:13:24Z
date available2017-05-08T23:13:24Z
date copyrightOctober, 1982
date issued1982
identifier issn0094-4289
identifier otherJEMTA8-26889#280_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/95865
description abstractAn analysis of test system misalignment is presented for the creep test. Sheet type rectangular 1100-0 aluminum specimens are used for discussion. It is found that the creep strain at the geometric centerline of the specimen is different than that at the neutral axis. However, this difference in the creep strain decreases with time. Generally, the effect of misalignment decreases with creep time. Creep tests conducted with long pullrods and large initial strain level (high creep stress) will tend to minimize the effect of misalignment.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalysis of Test System Misalignment in the Creep Test
typeJournal Paper
journal volume104
journal issue4
journal titleJournal of Engineering Materials and Technology
identifier doi10.1115/1.3225077
journal fristpage280
journal lastpage284
identifier eissn1528-8889
keywordsCreep
keywordsAluminum AND Stress
treeJournal of Engineering Materials and Technology:;1982:;volume( 104 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record