description abstractA numerical technique is presented to evaluate and correct the zero-strain reference points determined experimentally for certain in-vivo strain rosette applications on long bones. The method is used to determine whether significant transverse stresses are present at the gage site during in-vivo activities. If transverse stresses are shown to be negligible, the experimentally determined zeroes can be appropriately adjusted to provide an increased accuracy of the strain measurements. In addition, the transverse Poisson’s ratio is calculated and can be incorporated in subsequent in-vivo stress calculations.
publisherThe American Society of Mechanical Engineers (ASME)
titleAccuracy Enchancement of In-Vivo Bone Strain Measurements and Analysis
typeJournal Paper
journal volume104
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3138353
journal fristpage226
journal lastpage231
identifier eissn1528-8951
keywordsBone
keywordsStrain measurement
keywordsStress
keywordsPoisson ratio AND Gages
treeJournal of Biomechanical Engineering:;1982:;volume( 104 ):;issue: 003